So I ran into some interesting errors when adding simple cores to my design. On ISE13.2 working with the ML510 I encountered these errors when adding one simple core.
At first I started out with a set of errors that looked like this:
----------------------------------------
ERROR:EDK:4182 - PORT:PLB_masterID - VEC evaluation of (C_SPLB_MID_WIDTH-1) failed - C:\Users\user1\Documents\Projects4\v2\pcores\data_checker_v1_00_a\data\data_checker_v2_1_0.mpd line 51
ERROR:EDK:4182 - PORT:PLB_BE - VEC evaluation of ((C_SPLB_DWIDTH/8)-1) failed - C:\Users\user1\Documents\Projects4\v2\pcores\data_checker_v1_00_a\data\data_checker_v2_1_0.mpd line 55
ERROR:EDK:4182 - PORT:PLB_wrDBus - VEC evaluation of (C_SPLB_DWIDTH-1) failed - C:\Users\user1\Documents\Projects4\v2\pcores\data_checker_v1_00_a\data\data_checker_v2_1_0.mpd line 60
ERROR:EDK:4182 - PORT:Sl_rdDBus - VEC evaluation of (C_SPLB_DWIDTH-1) failed - C:\Users\user1\Documents\Projects4\v2\pcores\data_checker_v1_00_a\data\data_checker_v2_1_0.mpd line 76
ERROR:EDK:4182 - PORT:PLB_masterID - VEC evaluation of (C_SPLB_MID_WIDTH-1) failed - C:\Users\user1\Documents\Projects4\v2\pcores\rx_serdes_v1_00_a\data\rx_serdes_v2_1_0.mpd line 57
ERROR:EDK:4182 - PORT:PLB_BE - VEC evaluation of ((C_SPLB_DWIDTH/8)-1) failed - C:\Users\user1\Documents\Projects4\v2\pcores\rx_serdes_v1_00_a\data\rx_serdes_v2_1_0.mpd line 61
ERROR:EDK:4182 - PORT:PLB_wrDBus - VEC evaluation of (C_SPLB_DWIDTH-1) failed - C:\Users\user1\Documents\Projects4\v2\pcores\rx_serdes_v1_00_a\data\rx_serdes_v2_1_0.mpd line 66
ERROR:EDK:4182 - PORT:Sl_rdDBus - VEC evaluation of (C_SPLB_DWIDTH-1) failed - C:\Users\user1\Documents\Projects4\v2\pcores\rx_serdes_v1_00_a\data\rx_serdes_v2_1_0.mpd line 82
----------------------------------------
To get around this, most of the time you see a VEC evaluation failed, you can just hardcode the values in the .mpd file to what they should be. When you do this you clear these but you get another set of errors as depicted below.
----------------------------------------
ERROR:EDK:4075 - INSTANCE: DDR2_SDRAM_DIMM1, PORT: SPLB0_Sl_rdDBus, CONNECTOR: mb_plb_Sl_rdDBus - calculated index is out of signal VEC range of [0:1087] - C:\Xilinx\13.2\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\mpmc_v6_04_a\data\mpmc_v2_1_0.mpd line 1013
ERROR:EDK:4075 - INSTANCE: PCI32_BRIDGE, PORT: Sl_RdDBus, CONNECTOR: mb_plb_Sl_rdDBus - calculated index is out of signal VEC range of [0:1087] - C:\Xilinx\13.2\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\plbv46_pci_v1_04_a\data\plbv46_pci_v2_1_0.mpd line 191
ERROR:EDK:4075 - INSTANCE: SysACE_CompactFlash, PORT: Sl_rdDBus, CONNECTOR: mb_plb_Sl_rdDBus - calculated index is out of signal VEC range of [0:1087] - C:\Xilinx\13.2\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\xps_sysace_v1_01_a\data\xps_sysace_v2_1_0.mpd line 121
ERROR:EDK:4075 - INSTANCE: mdm_0, PORT: Sl_rdDBus, CONNECTOR: mb_plb_Sl_rdDBus - calculated index is out of signal VEC range of [0:1087] - C:\Xilinx\13.2\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\mdm_v2_00_b\data\mdm_v2_1_0.mpd line 159
ERROR:EDK:4075 - INSTANCE: xps_intc_0, PORT: Sl_rdDBus, CONNECTOR: mb_plb_Sl_rdDBus - calculated index is out of signal VEC range of [0:1087] - C:\Xilinx\13.2\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\xps_intc_v2_01_a\data\xps_intc_v2_1_0.mpd line 130
ERROR:EDK:4075 - INSTANCE: blink_test_0, PORT: Sl_rdDBus, CONNECTOR: mb_plb_Sl_rdDBus - calculated index is out of signal VEC range of [0:1087] - C:\Users\user1\Documents\Projects4\v2\pcores\blink_test_v1_00_a\data\blink_test_v2_1_0.mpd line 72
ERROR:EDK:4075 - INSTANCE: data_gen_0, PORT: Sl_rdDBus, CONNECTOR: mb_plb_Sl_rdDBus - calculated index is out of signal VEC range of [0:1087] - C:\Users\user1\Documents\Projects4\v2\pcores\data_gen_v1_00_a\data\data_gen_v2_1_0.mpd line 75
ERROR:EDK:4075 - INSTANCE: tx_serdes_0, PORT: Sl_rdDBus, CONNECTOR: mb_plb_Sl_rdDBus - calculated index is out of signal VEC range of [0:1087] - C:\Users\user1\Documents\Projects4\v2\pcores\tx_serdes_v1_00_a\data\tx_serdes_v2_1_0.mpd line 79
ERROR:EDK:4073 - INSTANCE: mb_plb, PORT: PLB_BE, CONNECTOR: mb_plb_PLB_BE - 16 bit-width connector assigned to 8 bit-width port - C:\Users\user1\Documents\Projects4\v2\_xps_tempmhsfilename.mhs line 112
ERROR:EDK:4073 - INSTANCE: mb_plb, PORT: PLB_masterID, CONNECTOR: mb_plb_PLB_masterID - 3 bit-width connector assigned to 2 bit-width port - C:\Users\user1\Documents\Projects4\v2\_xps_tempmhsfilename.mhs line 112
ERROR:EDK:4073 - INSTANCE: mb_plb, PORT: PLB_wrDBus, CONNECTOR: mb_plb_PLB_wrDBus - 128 bit-width connector assigned to 64 bit-width port - C:\Users\user1\Documents\Projects4\v2\_xps_tempmhsfilename.mhs line 112
----------------------------------------
These errors are fairly bizarre since I didn't really touch anything. To fix the errors, simply ignore the beginning ones about VEC signal out of range, and jump straight to the last ones at the end about the PORTS. The trick is to manually change the the widths in the .mpd to the values the errors are requesting.
No comments:
Post a Comment